Question
- What is the approval leakage limit according to RESNET-approved testing protocol for total duct leakage testing for a home at rough-in?
- < 2 CFM25 per 100 ft2 of conditioned floor area
- < 4 CFM25 per 100 ft2 of conditioned floor area
- < 2 CFM25 per 50 ft2 of conditioned floor area
- < 4 CFM25 per 50 ft2 of conditioned floor area
- How should a blower door and duct tester be installed for conducting a duct leakage to the outdoors test?
- The blower door should be set up to pressurize the home and the duct tester should be set up to pressurize the duct system.
- The blower door should be set up to depressurize the home and the duct tester should be set up to depressurize the duct system.
- Either a. or b.
- During a test for duct leakage to the outdoors, the first measurement with the duct tester pressure probe in the return duct read a leakage of 40 CFM, and the second measurement with the duct tester pressure probe in a supply duct as far as possible from the return the duct tester is connected to read a leakage of 120 CFM. What is the average measured duct leakage to the outdoors, and where is the greater source of leakage?
- What steps are done differently in a duct leakage to the outdoors test compared to a total duct leakage test?